Specifications BES 516-325-E3-N-PU-05 BES02LE
Inductive NAMUR sensors and switching amplifiers make it easy to detect conditions within sensitive areas in a non-contacting manner. The sensors are placed inside the work area and the switching amplifiers are placed outside. This assists with process stability.
In addition to standard versions, we also offer high pressure variants for monitoring end positions in hydraulic cylinders or for monitoring the positions of valves. There are explosion-proof variants for explosion hazard systems or rooms in Zones 1 and 2. In addition, proven models are available for applications in the semiconductor industry.
Features BES 516-325-E3-N-PU-05 BES02LE
Dimension: Ø 12 x 30 mm
Style: M12x1
Installation: for flush mounting
Range: 2 mm
Interface: NAMUR
Switching frequency: 1000 Hz
Housing material: Brass
Surface protection: nickel plated
Material sensing surface: PA 12
Connection: Cable, 5.00 m, PUR
Operating voltage Ub: 7.7...9 VDC
Ambient temperature: -25...70 °C
IP rating: IP67
Approval/Conformity: CE, EAC, WEEE