We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Keyence
Country
Japan
Name
GL-R44H
Type
Mounting bracket
Description
Haupteinheit, Handschützende Ausführung, 44 optische Achsen
Stock availability:
On request
If you are questing Keyence GL-R44H , make contact with FAMAGA, the world's main supplier of industrial equipment. Our company has advanced for more than ten years - these are cycles of experience, which are symbolized in the quality of products and personalseparate attention to each purchaser. We esteem everyone, who joined with us - thus, our regular buyers receive the most favorable purchase forms and discounts on the industrial equipment market. Nowadays, there are more than 4000 such customers, and we constantly sign new agreements. More than 600 contracts are concluded per day, because FAMAGA delivers all over the earth Germany, United Kingdom, Eswatini, Italy, Fiji, Belize, Sweden, Malawi, Costa Rica, North Korea, Slovakia, Iran, Libya, Russia, Lebanon, Monaco, Eritrea, Kuwait, Haiti, Azerbaijan, United Arab Emirates, Pakistan, Mongolia, Philippines, Indonesia, Guyana, Uzbekistan, Seychelles, Uganda, Mozambique, Syria, Mauritania, Rwanda, Tajikistan, Israel, Albania, Estonia, Armenia, Switzerland, Egypt, Senegal, Poland, Sierra Leone, Nepal, Bosnia and Herzegovina, United States, Tonga. A well-shaped logistics system and a partnership network let us to dispatch our goods anywhere in the world as soon as possible without discrediting product quality.
A specific source of honor for FAMAGA is its staff members, each of whom contributes to common cause. We call into our team only specialists, who already have experience in the range of industrial equipment.
All items from FAMAGA are affirmed - we are responsible for the cause of our work. At this moment, more than 10 million units of products have been delivered, and this quantity is rising every day. We are glad that consumers choose FAMAGA again and again, and we are glad to make more exceptional and technologically developed industrial equipment so as to stay on the top.
To request or book, get in touch with us or send a message to the online chat on our site. You can also dispatch a list of the needful equipment to the email of our company - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
Model | GL-R44H | ||
Detection capability | o25 mm | ||
Beam axis spacing/Lens diameter | 20 mm / o5 | ||
Detecting distance | 0.2 to 15 m*1 | ||
Effective aperture angle | Max. ±2.5° (When operating distance is 3 m or more) | ||
Light source | Infrared LED (870 nm) | ||
Response time (OSSD) (ms) | Wire synchronisation, One-line or Optical synchronisation system (Channel 0) | ON>OFF | 9.2 |
OFF>ON | 52.6*2 | ||
All blocked>ON | 73.5*3 | ||
Optical synchronisation system (Channel A or B) | ON>OFF | 12.9 | |
OFF>ON | 58.2*2 | ||
All blocked>ON | 88.6*3 | ||
Detection mode | Turns on when no interruptions are present in the detection zone | ||
Synchronisation between the transmitter and receiver | Optical synchronisation or Wire synchronisation (Determined by wiring) | ||
Light interference prevention function | Prevents mutual interference in up to two GL-R systems. Optical synchronization: prevented by Channel A and B with setting switch Wire synchronization: prevented automatically | ||
Control output (OSSD output) | Output | 2 transistor outputs. (PNP or NPN is determined by the cable type) | |
Max. load current | 500 mA*4 | ||
Residual voltage (during ON) | Max. 2.5 V (with a cable length of 5 m) | ||
OFF state voltage | Max. 2.0 V (with a cable length of 5 m) | ||
Leakage current | Max. 200 µA | ||
Max. capacitive load | 2.2 µF | ||
Load wiring resistance | Max. 2.5 ? | ||
Supplemental output (Non-safety-related output) | AUX | transistor outputs. (PNP or NPN is determined by the cable type) Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 5 m) | |
Error output | |||
Muting lamp output | Incandescent lamp (24 VDC, 1 to 5.5 W) LED lamp (load current: 10 to 230 mA) can be connected. | ||
External input | When using a PNP output cable | EDM input Wait input Reset input Muting input 1, 2 Override input | ON voltage: 10 to 30 V OFF voltage: Open or 0 to 3 V Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only) |
When using an NPN output cable | ON voltage: 0 to 3 V OFF voltage: Open or 10 V or more Up to the power voltage Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only) | ||
Rating | Power voltage | 24 VDC ±20%, ripple (P-P) 10% or less, Class 2 | |
Power supply | Current consumption (Max.) (mA) | Transmitter | 66 |
Receiver | 77 | ||
Protection circuit | Reverse current protection, short-circuit protection for each output, surge protection for each output | ||
Approved standards | EMC | EMS | IEC61496-1, EN61496-1, UL61496-1 |
EMI | EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA | ||
Safety | IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD) IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3) EN ISO13849-1:2015 (Category 4, PLe) UL508 UL1998 | ||
Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) | |
Overvoltage category | II | ||
Ambient light | Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less | ||
Operating ambient temperature | -10 to +55 °C (No freezing) | ||
Storage temperature | -25 to +60 °C (No freezing) | ||
Operating relative humidity | 15 to 85 % RH (No condensation) | ||
Storage relative humidity | 15 to 95 % RH | ||
Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions | ||
Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | ||
Material | Main unit case | Aluminium | |
Upper case/lower case | Nylon (GF 30%) | ||
Front cover | Polycarbonate, SUS304 | ||
Weight | Transmitter | 1220 g | |
Receiver | |||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 1.0 m. *2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms. *3 “All blocked” means the situation where the GL-R operates in optical synchronisation system and the transmitter and receiver is not synchronised (top and bottom beam axes are both blocked). In this situation, the response time is longer because the GL-R synchronises the transmitter and receiver fi rst and then determines the clear or blocked. *4 When the GL-R is used under surrounding air temperatures between 50 to 55°C, the Maximum load current should not exceed 350 mA. |