We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Model | SL-R11 | ||
Response speed FSD1, 2 AUX | 24 ms (including sensor response time)*1 | ||
Safety light curtain | SL-C Series | ||
FSD 1,2 | 230 VAC 4 A 30 VDC 2 A (resistive load) 230 VAC 2 A (cos O = 0.3) (inductive load) 30 VDC 1 A (cos O = 0.3) (inductive load) | ||
SL-R11 output | Lifespan | Mechanical life: 10 million times min. Electrical life: 100000 times min. | |
Response speed when E-STOP is input | 20 ms | ||
AUX | 125 VAC 0.5 A 30 VDC 2 A (resistive load) 125 VAC 0.25 A (cos O = 0.3) (inductive load) 30 VDC 1 A (cos O = 0.3) (inductive load) | ||
Approved standards | EMC | EMS | UL61496-1*2 |
EMI | FCC Part 15 Class A*2 | ||
Safety | UL61496-1 (type 4 ESPE) UL61496-2 (type 4 AOPD) UL508*2 | ||
Rating | Power voltage | 24 VDC ±10 %, Ripple (P-P) 10 % or less | |
Current consumption | 150 mA or less (for SL-R11 only) | ||
Environmental resistance | Enclosure rating | IP20 (IEC60529) Install in control panels which is equal to or greater than IP54 | |
Operating ambient temperature | -10 to +55 °C (No freezing) | ||
Storage temperature | -10 to +60 °C (No condensation | ||
Operating relative humidity | 35 to 85 % RH (No condensation) | ||
Storage relative humidity | 35 to 95 % RH (No condensation) | ||
Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions | ||
Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | ||
Material | Polycarbonate | ||
Weight | Approx. 380 g | ||
*1 The OFF > ON return time is 150 ms. *2 Evaluated in combination with the SL-C Series. |