We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are pursuing Keyence SL-V79F , get in touch with FAMAGA, the world's key producer of factory-made equipment. Our company has lasted for more than ten years - these are ages of experience, which are illustrated in the quality of spare parts and special attention to each consumer. We respect everyone, who worked with us - thus, our regular buyers obtain the most flexible purchase terms and discounts on the machine made streamlined equipment market. Today, there are more than 3500 such buyers, and we constantly sign new agreements. More than 700 affairs are settled per day, because FAMAGA delivers all over the globe Germany, United Kingdom, The Bahamas, Iceland, Angola, Sri Lanka, Iraq, Ireland, Equatorial Guinea, Montenegro, Argentina, El Salvador, Malawi, Togo, Gambia, Georgia, Paraguay, Lithuania, Niger, Algeria, Tonga, Jordan, Cameroon, Senegal, Liberia, Norway, Eswatini, Central African Republic, South Sudan, Liechtenstein, Austria, Ghana, Belize, Libya, Luxembourg, Armenia, Kiribati, Denmark, Sudan, Greece, Czech Republic, Namibia, Iran, Kyrgyzstan, Turkey, Kenya, Nepal. A well-elaborated logistics bond and a partnership network guide us to send our items anywhere in the globe on-time without discrediting product quality.
A specific source of honor for FAMAGA is its staff members, each of whom contributes to our work. We invite into our team only specialists, who already have experience in the range of factory-made equipment.
All goods from FAMAGA are assured - we are responsible for the cause of our work. Nowadays, more than 10 million units of products have been supplied, and this bulk is rising every day. We are pleased that consumers choose FAMAGA again and again, and we are eager to make more exceptional and technologically modern industrial equipment so as stay in control.
To ask a question or book, contact us or send a message to the online chat on our official website. You can also dispatch a list of the desirable equipment to the email of corporation - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
Model | SL-V79F | ||
Detection capability | o14 mm | ||
Beam axis spacing/Lens diameter | 10 mm/o4 mm | ||
Effective aperture angle | Max. ±2.5 ° (When operating distance is 3 m or more) | ||
Working distance | 0.1 m to 7.0 m | ||
Response time (ms) | ON>OFF | 16.8*1 | |
OFF>ON | 56.8*1 | ||
Light source | Infrared LED (850 nm) | ||
Operation mode | Turns on when no interruptions are present in the detection zone (excluding when the muting function is used) | ||
OSSD output | Output | 2 outputs each for PNP and NPN. Can be changed by using the connector cable. | |
Max. l oad current | 500 mA*2 | ||
Residual vol tage (during ON) | Max. 2.5 V (with a cable length of 7 m) | ||
Leakage current | Max. 100 µA*3 | ||
Max. capacitive load | 2.2 µF (with a load resistance of 100 ?) | ||
Load wiring resistance | Max. 2.5 ?*4 | ||
Non safety-rel atedoutput | AUX | Output with automatic PNP/NPN switching function, 50 mA max. | |
Interlock-reset-ready output | |||
Alarm output | |||
Clear/blocked output | |||
State information output 1, 2 | |||
Muting lamp output | Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected | ||
Input | EDM input | Short-circuit current 10 mA | |
Wait input | Short-circuit current 2.5 mA | ||
Reset input | |||
Muting input 1, 2 | |||
Override input | |||
Protection circuit | Reverse current protection, short-circuit protection for each output, surge protection for each output | ||
Approved standards | EMC | EMS | IEC61496-1, EN61496-1, UL61496-1 |
EMI | EN55011 Class A, FCC Part15B Class A | ||
Safety | IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD) IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe) UL508 UL1998 | ||
Rating | Power voltage | 24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less | |
Current consumption (mA) | When the Centre indicator is ON | Transmitter | 142*6 |
Receiver | 94*6 | ||
When the Centre indicator is OFF | Transmitter | 135*6 | |
Receiver | 85*6 | ||
Environmental resistance | Enclosure rating | IP65 (IEC60529) | |
Overvoltage category | II | ||
Ambient light | Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max. | ||
Operating ambient temperature | -10 to +55 °C (No freezing) | ||
Storage temperature | -25 to +60 °C (No freezing) | ||
Operating relative humidity | 15 to 85 % RH (No condensation) | ||
Storage relative humidity | 15 to 95 % RH | ||
Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions | ||
Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | ||
Material | Main unit case | Aluminium | |
Upper case/lower case | Zinc die-cast | ||
Front cover | Polycarbonate, SUS304 | ||
Weight | Transmitter | 620 g | |
Receiver | 635 g | ||
*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of theresponse times of al l the individual SL-V units, but the response time (OFF to ON) is the sameas that of a singl e SL-V unit. e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), andSL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms. *2 When used under ambient temperature between 45 to 55 °C, the maximum should not exceed 300 mA. *3 Applies to situations when power is either off or disconnected. *4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cable) must be 2.5 ? or less to ensure operations. If using the NPN output with a cable length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 ? or less. *5 When used under ambient temperature between 45 to 55 °C, use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA). *6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by 10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of both transmitter and receiver is fixed.) In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the OFF state. In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON state. |