We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Keyence
Country
Japan
Name
LV-N11CP
Type
Mounting bracket
Description
Laser sensor main amplifier , 10-30 VDC, PNP output, M8 connector
Stock availability:
On request
If you are seeking Keyence LV-N11CP , make contact with FAMAGA, the world's the best supplier of mechanized equipment. Our company has worked for more than ten years - these are years of experience, which are described in the quality of outcomes and private attention to each user. We understand everyone, who collaborated with us - therefore, our regular clients receive the most desirable purchase conditions and discounts on the industrial equipment market. At present, there are more than 4500 such customers, and we constantly compose new agreements. More than 750 transactions are made per day, because FAMAGA operates all over the globe Germany, United Kingdom, Zambia, Thailand, Costa Rica, Portugal, Azerbaijan, Liberia, Turkey, Malawi, Bhutan, East Timor, Lebanon, Malta, Gambia, Uzbekistan, Serbia, Suriname, South Sudan, Saudi Arabia, Japan, Belize, Panama, Iceland, Benin, Moldova, Peru, Antigua and Barbuda, Equatorial Guinea, Central African Republic, Lithuania, Poland, India, Niger, North Korea, Malaysia, Argentina, El Salvador, Latvia, Libya, Israel, Mali, Qatar, Czech Republic, Iran, Rwanda, Sudan, Kazakhstan, Australia, Ukraine, Kuwait. A well-shaped logistics system and a partnership network let us to deliver our elements anywhere in the world quickly without damaging product quality.
A specific source of good name for FAMAGA is its team members, each of whom contributes to our work. We call into our team only specialists, who already have experience in the field of manufacturing equipment.
All products from FAMAGA are guaranteed - we are responsible for the result of our work. At the moment, more than 10 million units of products have been provided, and this quantity is growing every day. We are happy that buyers choose FAMAGA again and again, and we are eager to make more advanced and technologically modern industrial equipment so as not to lower the bar.
To inquire or book, contact us or write to the online chat on our official website. You can also forward a list of the needful equipment to the email of corporation - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
Model | LV-N11CP | |
Type | 1 output | |
Output | PNP | |
Cable/connector | M8 connector | |
Main/Expansion unit | Main unit | |
I/O | Control outputs | 1 output |
External input | 1 input | |
Monitor output | None | |
Response time | 80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1 | |
Output selection | LIGHT-ON/DARK-ON (switch-selectable) | |
Timer function | Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9,999 ms, Maximum error against the setting value: ±10% max. | |
Control outputs | PNP open collector 30 V, Residual voltage 1.2 V or less (Output current: 10 mA or less) / 2.2 V or less (Output current: 10 to 100 mA) (Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less (Multiple connections) 1 output max: 20 mA or less | |
Monitor output | - | |
External input | Input time 2 ms (ON)/20 ms (OFF) or more*2 | |
Multiple connections to expansion units | Up to 17 units can be connected in total (two-output type is treated as two units) | |
Protection circuit | Reverse polarity protection, Over-current protection, Surge absorber | |
Number of interference prevention units | Connected to other than LV-S31: 0 for HIGH SPEED, 2 for FINE/TURBO/SUPER, 4 for ULTRA/MEGA, Connected to LV-S31: 2 for FINE, 4 for TURBO/SUPER/ULTRA/MEGA*3 | |
Case size | H 32.6 mm ? W 9.8 mm ? L 78.7 mm | |
Rating | Power voltage | 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS |
Power consumption | Normal: 950 mW or less (at 30 V. 33 mA at 24 V, 60 mA or less at 12 V)*4 Eco on mode: 815 mW or less (at 30 V. 29 mA at 24 V, 52 mA or less at 12 V)*4 Eco Full mode: 650 mW or less (at 30 V. 24 mA at 24 V, 40 mA or less at 12 V) *5 | |
Environmental resistance | Ambient temperature | -20 to +55 °C (No freezing)*6 |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions | |
Material | Cable | PVC |
Case | Main unit and cover material: Polycarbonate | |
Weight | Approx. 20 g | |
*1 80 µs cannot be selected when the LV-S31/S62/S63 is connected *2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected. *3 These numbers double when 'DOUBLE' is selected. *4 Increases 30 mW (1 mA) for High Speed mode. *5 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load. Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode. (1.15 ? 860 mW ? 1) + (1.15 ? 860 mW ? 2) = 2967 mW max. *6 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit. One or two more units connected: -20 °C to +55 °C , 3 to 10 more units connected: -20 °C to +50 °C, 11 to 16 more units connected: -20 °C to +45 °C. When using 2-outputs, one unit is counted as two units. |