We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are questing Keyence LV-N10 , contact FAMAGA, the world's key producer of factory-made equipment. Our company has lasted for more than ten years - these are ages of experience, which are expressed in the quality of products and individual attention to each consumer. We appreciate everyone, who worked with us - therefore, our regular clients obtain the most favorable purchase terms and discounts on the industrial equipment market. Today, there are more than 4000 such clients, and we constantly compose new agreements. More than 650 affairs are settled per day, because FAMAGA operates all over the world Germany, United Kingdom, Albania, Swaziland, Equatorial Guinea, Italy, Fiji, Japan, Yemen, Romania, Oman, Bangladesh, Colombia, Philippines, Monaco, The Bahamas, Iceland, New Zealand, Azerbaijan, Eritrea, Chad, Russia, Denmark, Luxembourg, Namibia, United States, Mongolia, The Gambia, Mauritius, Sweden, Finland, Rwanda, China, Guatemala, Croatia, North Korea, Benin, Belize, Kazakhstan, Seychelles, Burkina Faso, Pakistan, Tonga, Mozambique, Kuwait, South Korea, East Timor, Afghanistan, Nepal, Bolivia, Thailand. A advanced logistics bond and a partnership network guide us to conduct our items anywhere in the world on-time without undermining product quality.
A specific source of good name for FAMAGA is its workers, each of whom contributes to our work. We propose into our team only specialists, who already have experience in the field of industrial equipment.
All goods from FAMAGA are ensured - we are responsible for the outcome of our work. At the moment, more than 10 million units of products have been shipped, and this number is increasing every day. We are proud that consumers choose FAMAGA again and again, and we are pleased to make more advanced and technologically developed industrial equipment so as not to lower the bar.
To inquire or place an order, call us by phone or send a message to the online chat on our official website. You can also send a list of the required equipment to the email of our company - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
Model | LV-N10 | |
Type | Zero line | |
Cable/connector | - | |
Main/Expansion unit | Expansion unit | |
I/O | Control outputs | None |
External input | ||
Monitor output | ||
Response time | 80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1 | |
Output selection | LIGHT-ON/DARK-ON (switch-selectable) | |
Timer function | Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9,999 ms, Maximum error against the setting value: ±10% max. | |
Control outputs | NPN open collector 30 V, Residual voltage 1 V or less (Output current: 10 mA or less) / 2 V or less (Output current: 10 to 100 mA) (Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less (Multiple connections) 1 output max: 20 mA or less | |
Monitor output | - | |
External input | Input time 2 ms (ON)/20 ms (OFF) or more*2 | |
Multiple connections to expansion units | Up to 17 units can be connected in total (two-output type is treated as two units) | |
Protection circuit | Reverse polarity protection, Over-current protection, Surge absorber | |
Number of interference prevention units | Connected to other than LV-S31: 0 for HIGH SPEED, 2 for FINE/TURBO/SUPER, 4 for ULTRA/MEGA, Connected to LV-S31: 2 for FINE, 4 for TURBO/SUPER/ULTRA/MEGA*3 | |
Case size | H 32.6 mm ? W 9.8 mm ? L 78.7 mm | |
Rating | Power voltage | 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS |
Power consumption | Normal: 830 mW or less (at 30 V. 30 mA at 24 V, 56 mA or less at 12 V)*4 Eco on mode: 710 mW or less (at 30 V. 26 mA at 24 V, 48 mA or less at 12 V)*4 Eco Full mode: 550 mW or less (at 30 V. 21 mA at 24 V, 40 mA or less at 12 V) *5 | |
Environmental resistance | Ambient temperature | -20 to +55 °C (No freezing)*6 |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions | |
Material | Cable | PVC |
Case | Main unit and cover material: Polycarbonate | |
Weight | Approx. 20 g | |
*1 80 µs cannot be selected when the LV-S31/S62/S63 is connected *2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected. *3 These numbers double when 'DOUBLE' is selected. *4 Increases 30 mW (1 mA) for High Speed mode. *5 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load. Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode. (1.15 ? 860 mW ? 1) + (1.15 ? 860 mW ? 2) = 2967 mW max. *6 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit. One or two more units connected: -20 °C to +55 °C , 3 to 10 more units connected: -20 °C to +50 °C, 11 to 16 more units connected: -20 °C to +45 °C. When using 2-outputs, one unit is counted as two units. |