We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Keyence
Country
Japan
Name
LV-N12CP
Type
Mounting bracket
Description
Amplifier, M8 Connector, Expansion unit, PNP
Stock availability:
On request
If you are seeking Keyence LV-N12CP , contact FAMAGA, the world's prime vendor of factory-made equipment. Our company has advanced for more than ten years - these are ages of experience, which are expressed in the quality of products and private attention to each client. We praise everyone, who conspired with us - thus, our regular clients procure the most favorable purchase terms and discounts on the machine made streamlined equipment market. At this time, there are more than 4 thousand such customers, and we constantly compose new agreements. More than 600 affairs are settled per day, because FAMAGA delivers all over the world Germany, United Kingdom, Serbia, Brunei, Bangladesh, Guinea-Bissau, Guyana, Eritrea, Indonesia, Oman, Honduras, Central African Republic, Papua New Guinea, Georgia, Netherlands, Japan, Armenia, Iran, Turkmenistan, Singapore, Malawi, Fiji, Tonga, Cape Verde, Greece, Botswana, Nigeria, El Salvador, Syria, Morocco, Peru, Hungary, Togo, United States, Jamaica, Cameroon, Pakistan, Azerbaijan, Paraguay, Poland, Mauritania, Finland, Malta, South Korea, Yemen, Belarus, Dominica, Comoros, Swaziland, Vietnam, Senegal. A well-shaped logistics connection and a partnership network allow us to deliver our products anywhere in the globe promptly without damaging product quality.
A particular source of good name for FAMAGA is its team members, each of whom contributes to our work. We call into our team only experts, who already have experience in the range of machine made streamlined equipment.
All spare parts from FAMAGA are guaranteed - we are responsible for the aftereffect of our work. Nowadays, more than 10 million units of products have been supplied, and this amount is growing every day. We are glad that clients choose FAMAGA again and again, and we are eager to make more exceptional and technologically developed industrial equipment so as stay in control.
To inquire or place an order, call us by phone or send a message to the online chat on our official website. You can also dispatch a list of the necessary equipment to the email of our company - we will contact you ourselves with a made commercial proposal from FAMAGA.
Model | LV-N12CP | |
Type | 1 output | |
Output | PNP | |
Cable/connector | M8 connector | |
Main/Expansion unit | Expansion unit | |
I/O | Control outputs | 1 output |
External input | 1 input | |
Monitor output | None | |
Response time | 80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1 | |
Output selection | LIGHT-ON/DARK-ON (switch-selectable) | |
Timer function | Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9,999 ms, Maximum error against the setting value: ±10% max. | |
Control outputs | PNP open collector 30 V, Residual voltage 1.2 V or less (Output current: 10 mA or less) / 2.2 V or less (Output current: 10 to 100 mA) (Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less (Multiple connections) 1 output max: 20 mA or less | |
Monitor output | - | |
External input | Input time 2 ms (ON)/20 ms (OFF) or more*2 | |
Multiple connections to expansion units | Up to 17 units can be connected in total (two-output type is treated as two units) | |
Protection circuit | Reverse polarity protection, Over-current protection, Surge absorber | |
Number of interference prevention units | Connected to other than LV-S31: 0 for HIGH SPEED, 2 for FINE/TURBO/SUPER, 4 for ULTRA/MEGA, Connected to LV-S31: 2 for FINE, 4 for TURBO/SUPER/ULTRA/MEGA*3 | |
Case size | H 32.6 mm ? W 9.8 mm ? L 78.7 mm | |
Rating | Power voltage | 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS |
Power consumption | Normal: 950 mW or less (at 30 V. 33 mA at 24 V, 60 mA or less at 12 V)*4 Eco on mode: 815 mW or less (at 30 V. 29 mA at 24 V, 52 mA or less at 12 V)*4 Eco Full mode: 650 mW or less (at 30 V. 24 mA at 24 V, 40 mA or less at 12 V) *5 | |
Environmental resistance | Ambient temperature | -20 to +55 °C (No freezing)*6 |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions | |
Material | Cable | PVC |
Case | Main unit and cover material: Polycarbonate | |
Weight | Approx. 20 g | |
*1 80 µs cannot be selected when the LV-S31/S62/S63 is connected *2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected. *3 These numbers double when 'DOUBLE' is selected. *4 Increases 30 mW (1 mA) for High Speed mode. *5 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load. Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode. (1.15 ? 860 mW ? 1) + (1.15 ? 860 mW ? 2) = 2967 mW max. *6 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit. One or two more units connected: -20 °C to +55 °C , 3 to 10 more units connected: -20 °C to +50 °C, 11 to 16 more units connected: -20 °C to +45 °C. When using 2-outputs, one unit is counted as two units. |