We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are inspecting Keyence LV-12SA , get in touch with FAMAGA, the world's foremost company of mechanized equipment. Our company has operated for more than ten years - these are years of experience, which are illustrated in the quality of spare parts and particular attention to each orderer. We respect everyone, who engaged with us - thus, our regular purchasers pick up the most flexible purchase conditions and discounts on the machine made streamlined equipment market. At this moment, there are more than 3500 such purchasers, and we constantly arrange new agreements. More than 700 transactions are made per day, because FAMAGA delivers all over the globe Germany, United Kingdom, Cameroon, Moldova, Seychelles, Senegal, Portugal, Iraq, Argentina, Sweden, Poland, Swaziland, Guinea, Belgium, The Gambia, Mauritania, Thailand, Netherlands, Jordan, Cyprus, Eswatini, Georgia, Czech Republic, Hungary, Malta, Cape Verde, Ecuador, Norway, Denmark, Turkey, Finland, Iceland, Kiribati, Tonga, Uruguay, Nigeria, Brazil, India, Kyrgyzstan, Zambia, Niger, Bangladesh, Ireland. A well-shaped logistics network and a partnership network allow us to ship our goods anywhere in the globe as soon as possible without damaging product quality.
A special source of repute for FAMAGA is its personnel, each of whom contributes to our work. We call into our team only professionals, who already have experience in the range of factory-made equipment.
All outcomes from FAMAGA are affirmed - we are responsible for the cause of our work. Nowadays, more than 10 million units of products have been supplied, and this bulk is amounting every day. We are pleased that customers choose FAMAGA again and again, and we are glad to make more exceptional and technologically modern industrial equipment so as stay in control.
To request or book, contact us or write to the online chat on our official website. You can also dispatch a list of the desirable equipment to the email of corporation - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
Model | LV-12SA | ||
Type | Expansion unit (1 line) | ||
Main unit/Expansion unit | |||
Applicable model | LV-S61/S41/S41L/S31/S71/S72 | ||
Control output | NPN open-collector ? 2 channels, 40 VDC maximum, 100 mA or less per output | ||
Response time | ExceptLV-S31 | ULTRA | 4 ms |
SUPER | 2 ms | ||
TURBO | 500 µs | ||
FINE | 250 µs | ||
HSP | 80 µs | ||
LV-S31standard mode | 500 µs | ||
LV-S31standard mode | SPED2 | 2 ms | |
SPED3 | 8 ms | ||
SPED4 | 32 ms | ||
LV-S31High-speed mode | 250 µs | ||
Control input | Light emission stop input, external calibration, set value bank selection input, or received light intensity shift input | ||
Number of interference prevention units | ULTRA | 4 | |
SUPER | |||
TURBO | 2 | ||
FINE | |||
HSP | 0 | ||
Unit expansion | Up to 16 units (17 units total including the main unit)*1 | ||
Rating | Power voltage | 12 to 24 VDC, Ripple (P-P) 10 % or less, Class 2*2 | |
Power consumption | Normal | 1.5 W or less (62.5 mA or less at 24 V) | |
Ratings | Eco-Half Eco-All | 1.35 W or less (57.3 mA or less at 24 V) | |
Environmental resistance | Ambient temperature | -10 to +55 °C (No freezing)*3 | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis | ||
Material | Main unit | Main body, cover: Polycarbonate | |
Weight | Approx. 80 g (including 2 m cable) | ||
*1 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is *2 When more than 8 units connected, be sure to use supply voltage 24 VDC Ripple (P-P) 10 % max. *3 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows: 1 to 2 units connected: -10 to +55 °C, 3 to 10 units connected: -10 to +50 °C, 11 to 16 units connected: -10 to +45 °C |