We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are looking for Keyence PS-N11CN , make contact with FAMAGA, the world's influential vendor of machine made equipment. Our company has functioned for more than ten years - these are ages of experience, which are described in the quality of goods and personalseparate attention to each purchaser. We praise everyone, who joined with us - thus, our regular customers procure the most desirable purchase terms and discounts on the machine made streamlined equipment market. Today, there are more than 3500 such customers, and we constantly form new agreements. More than 700 affairs are settled per day, because FAMAGA delivers all over the globe Germany, United Kingdom, Morocco, Guinea, Nicaragua, Grenada, Tunisia, Peru, Kiribati, Burma, Panama, Sierra Leone, The Bahamas, Iraq, Philippines, Uzbekistan, Samoa, South Korea, Luxembourg, Bangladesh, Kyrgyzstan, Eritrea, Malta, Laos, Paraguay, Turkmenistan, Chad, Slovakia, Montenegro, Lithuania, Chile, Cameroon, Uganda, Kazakhstan, Mozambique, Argentina, Denmark, Libya, Nepal, Rwanda, East Timor, Austria, Kuwait, Norway, Senegal. A well-developed logistics connection and a partnership network guide us to deliver our items anywhere in the globe on-time without compromising product quality.
A specific source of pride for FAMAGA is its employees, each of whom contributes to our work. We accept into our team only specialists, who already have experience in the range of factory-made equipment.
All spare parts from FAMAGA are guaranteed - we are responsible for the cause of our work. Nowadays, more than 10 million units of products have been supplied, and this bulk is growing every day. We are pleased that consumers choose FAMAGA again and again, and we strive to make more exceptional and technologically modern industrial equipment so as stay in control.
To consult or book, contact us or send a message to the online chat on our official website. You can also dispatch a list of the desirable equipment to the email of corporation - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
Model | PS-N11CN | |
Type | M8 connector | |
Output | NPN | |
Main unit/Expansion unit | Main unit | |
I/O | Control outputs | 1 output |
External input | 1 input | |
Response time | 500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) | |
Output selection | LIGHT-ON/DARK-ON (switch-selectable) | |
Timer function | Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9999 ms, Maximum error against the setting value: ±10% max. | |
Control output | NPN open collector 30 V, (without expansion) 100 mA max., (with expansion) 20 mA max, residual voltage 1 V max. (when the out current is 10 mA or less)/2 V max. (when the output current is 10 to 100 mA) | |
External input | Input time 2 ms (ON)/20 ms (OFF) or more*1 | |
Unit expansion | Up to 17 main units can be connected | |
Protection circuit | Reverse polarity protection, Over-current protection, Surge absorber | |
Number of interference prevention units | 4 for TURBO/SUPER/ULTRA/MEGA (When set to DOUBLE, the number of interference-prevention units will be doubled) | |
Case size | H 32.6 mm ? W 9.8 mm ? L 78.7 mm | |
Rating | Power voltage | 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS |
Power consumption | Normal: 810 mW or less (at 30V. 28 mA max. at 24 V, 34 mA max. at 12 V) Eco on mode: 700 mW or less (at 30V. 24 mA max. at 24 V, 27 mA max. at 12 V) Eco Full mode: 490 mW or less (at 30V. 17 mA max. at 24 V, 20 mA max. at 12 V) | |
Environmental resistance | Ambient temperature | -20 to +55 °C (No freezing)*2 |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions | |
Material | Case | Main unit and cover material: Polycarbonate |
Cable | PVC | |
Weight | Approx. 20 g | |
*1 Input time is 25 ms (ON)/25 ms (OFF) when the external calibration time is selected. *2 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a uni t . One or two more units connected: -20 to +55 °C , 3 to 10 more units connected: -20 to +50 °C, 11 to 16 more units connected: -20 to +45 °C . |