We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are inspecting Keyence EX-305V , contact FAMAGA, the world's prime distributor of streamlined equipment. Our company has progressed for more than ten years - these are years of experience, which are expressed in the quality of products and particular attention to each user. We appreciate everyone, who conspired with us - therefore, our regular purchasers accept the most favorable purchase conditions and discounts on the industrial equipment market. At this moment, there are more than 4000 such purchasers, and we constantly arrange new agreements. More than 650 transactions are made per day, because FAMAGA operates all over the world Germany, United Kingdom, Italy, Togo, Mozambique, Sri Lanka, Albania, Ghana, Zambia, Senegal, Egypt, Central African Republic, Chile, Singapore, Turkmenistan, South Korea, Georgia, Djibouti, Finland, United States, Benin, Brazil, Brunei, Cape Verde, Nicaragua, Tonga, Swaziland, Bulgaria, Fiji, Slovakia, Bolivia, Jamaica, South Sudan, East Timor, Madagascar, Laos, Nepal, Costa Rica, Haiti, Afghanistan, Yemen, Qatar, Libya. A well-shaped logistics series and a partnership network allow us to ship our goods anywhere in the world as soon as possible without damaging product quality.
A special source of repute for FAMAGA is its personnel, each of whom contributes to our work. We call into our team only professionals, who already have experience in the field of industrial equipment.
All outputs from FAMAGA are affirmed - we are responsible for the outcome of our work. At the moment, more than 10 million units of products have been shipped, and this number is amounting every day. We are proud that customers choose FAMAGA again and again, and we are glad to make more advanced and technologically developed industrial equipment so as not to lower the bar.
To request or place an order, call us by phone or write to the online chat on our official website. You can also send a list of the required equipment to the email of our company - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
Model | EX-305V*1 | |
Type | Sensor head | |
Amplifier unit | EX-V01(P) | |
Shape | o5.4 x 18 mm Cylindrical | |
Measuring range | 0 to 1 mm | |
Display range | -19999 to +19999 | |
Linearity | ±0.3% of F.S. | |
Resolution (No. of averaging measurements: 64) | 0.4 µm | |
Sampling rate | 40000 samplings max./sec. *2 | |
Display speed | 20 times/sec. | |
Display power | 7-segment 2-colour LED | |
Over-range alarm | ±FFFF is displayed. | |
Control output | NPN open-collector or non-voltage contact signal | |
Controloutput | Setting method | Upper/lower 2-level setting x 4 patterns (selectable) |
Response time | 0.075 ms (at maximum speed) | |
OFF-delay time | 60 ms (ON/OFF selectable) | |
Strobe output | NPN open-collector (HIGH, GO and LOW): 100 mA max. (40 V max.) | |
Analogue output voltage | Output voltage | ±5V |
Impedance | 100 ? | |
Response time | 0.075 ms (at maximum speed) | |
Temperature characteristics | 0.07% of F.S./°C *3 | |
Major functions | FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. | |
Rating | Power voltage | 24 VDC ±10 %, Ripple (P-P) 10 % or less |
Current consumption | 240 mA or less | |
Environmental resistance | Ambient temperature | -10 to +60 °C (No freezing) |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Weight | Approx. 45 g (including 3-m cable) | |
*1 The above data was obtained using an iron target (S45C, SS400, t=1 mm). When measuring aluminium, copper, or stainless steel targets, refer to the linear characteristics for these materials. *2 When the digital filter function is used, the sampling rate is 20000 sampling/sec. *3 When the distance between the sensor head and the target is within 50% of the measuring range. |