We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are seeking Keyence IV-2000M , contact FAMAGA, the world's major retailer of industrialized equipment. Our company has advanced for more than ten years - these are ages of experience, which are expressed in the quality of products and private attention to each customer. We appreciate everyone, who liased with us - therefore, our regular consumers bring in the most favorable purchase terms and discounts on the industrial equipment market. Today, there are more than 4000 such consumers, and we constantly make new agreements. More than 650 affairs are settled per day, because FAMAGA operates all over the world Germany, United Kingdom, Russia, Peru, Turkey, Malaysia, Namibia, Tonga, Brazil, Djibouti, Kyrgyzstan, India, Morocco, Mauritius, Luxembourg, Singapore, Oman, El Salvador, Qatar, Switzerland, Vietnam, Ukraine, Ireland, Japan, The Gambia, Kuwait, Zimbabwe, Egypt, Moldova, Swaziland, Kiribati, South Sudan, Central African Republic, Yemen, Comoros, Benin, North Korea, Belarus, Afghanistan, Latvia, Pakistan, Guatemala, Suriname, Zambia. A well-built logistics link and a partnership network guide us to dispatch our items anywhere in the world on-time without disreputing product quality.
A specific source of dignity for FAMAGA is its team members, each of whom contributes to our work. We request into our team only specialists, who already have experience in the field of industrial equipment.
All merchandises from FAMAGA are verified - we are responsible for the outcome of our work. At the moment, more than 10 million units of products have been shipped, and this number is ascending every day. We are proud that consumers choose FAMAGA again and again, and we are happy to make more advanced and technologically developed industrial equipment so as not to lower the bar.
To get some advice or place an order, call us by phone or send a message to the online chat on our official website. You can also send a list of the required equipment to the email of our company - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
Model | IV-2000M | |
Type | Long range | |
Installed distance | 300 to 2,000 mm | |
View | Installed distance 300 mm: 45 (H) x 33 (V) mm to installed distance 2,000 mm: 300 (H) x 225 (V) mm | |
Image sensor | Type | 1/3 inch monochrome CMOS |
Pixel | 752 (H) x 480 (V) | |
Focus adjustment | Manual | |
Exposure time | 1/10 to 1/25,000 | |
Lights | Illumination | Infrared LED |
Lighting method | Pulse lighting/DC lighting is switchable | |
Tools | Type | Shape Detection, Colour Area*1, Area*2, position adjustment |
Number | Detection tools: 16 tools, position adjustment tool: 1 tool*3 | |
Switch settings (programs) | 32 programmes | |
Image history | Numbers | 300 images*4*5 |
Condition | NG only/All is selectable*5 | |
Analysis information | OFF/Statistics/Histograms is switchable Statistics: Processing time (latest value, MAX, MIN, AVE), number of OKs, number of NGs, trigger numbers, trigger errors, judgement results list by tools Histograms: Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs *6 | |
Other functions | HDR, HighGain, Colour filters*1, Digital zoom*2, Brightness correction, Tilt correction, White balance*1, Mask outline, Mask area, Test run, ToolAutoTune, Input monitor, Output test, Security settings, Simulator*7 | |
Indicators | PWR/ERR, OUT, TRIG, STATUS, LINK/ACT | |
Input | Type | Non-voltage input/voltage input is switchable For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V) |
Inputs | 6 inputs (IN1 to IN6) | |
Function | IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions Assignable functions: Program switching, Clear error, External master image registration | |
Output | Type | Open collector output NPN/PNP is switchable, N.O./N.C. is switchable For open collector NPN output: Maximum rating 26.4 V 50 mA, remaining voltage 1.5 V or lower For open collector PNP output: Maximum rating 26.4 V 50 mA, remaining voltage 2 V or lower |
Outputs | 4 outputs (OUT1 to OUT4) | |
Function | Enable by assigning the optional functions Assignable functions: Total judgement result, RUN, BUSY, Error, Position adjustment result, Judgement result of each tool, Result of the logical operation of each tool, Main unit/expansion unit logical output | |
Ethernet | Standard | 100BASE-TX/10BASE-T*8 |
Connector | M12 4pin connector*8 | |
Network function | FTP client, EtherNet/IPTM, PROFINET | |
Rating | Power voltage | 24 VDC ±10 % (including ripple) |
Current consumption | 0.6 A or less | |
Environmental resistance | Enclosure rating | IP67*9 |
Ambient temperature | 0 to +50 °C (No freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions*10 | |
Shock resistance | 500 m/s2, 3 times in each of 6 directions*10 | |
Material | Main unit case: Aluminium die-casting, Packing: NBR, Front cover: Acrylic, Mounting adapter: POM | |
Weight | Approx. 270 g | |
*1 Colour type only *2 Possible with both the colour type and monochrome type *3 Tools can be installed by programmes. *4 When using the FTP client function: 210 pictures *5 Saves to the memory in the sensor. The images saved in the sensor can be backed up to the USB memory installed to the intelligent monitor (IV-M30) or to the PC by the software for IV (IV-H1). *6 This can be displayed on the intelligent monitor (IV-M30) or by software for IV (IV-H1). *7 Simulator can be used with the IV software (IV-H1). *8 This is for connection with the intelligent monitor (IV-M30) or software for IV (IV-H1). *9 Except when polarised filter attachment (OP-87436/OP-87437) is mounted *10 Except when IV-G dome attachment (IV-D10) is mounted |