We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are seeking Keyence IV-500C , get in touch with FAMAGA, the world's the best provider of manufacturing equipment. Our company has worked for more than ten years - these are cycles of experience, which are illustrated in the quality of spare parts and private attention to each buyer. We respect everyone, who collaborated with us - thus, our regular consumers get the most flexible purchase forms and discounts on the machine made streamlined equipment market. At this time, there are more than 3500 such consumers, and we constantly make new agreements. More than 700 proceedings are resolved per day, because FAMAGA delivers all over the globe Germany, United Kingdom, Liechtenstein, Nigeria, Indonesia, Cameroon, Samoa, Philippines, Burma, Benin, Kenya, Burkina Faso, Togo, Thailand, Uganda, India, Turkmenistan, Zimbabwe, Malawi, Azerbaijan, Malta, Eswatini, Denmark, Vietnam, Namibia, Iraq, Belize, Senegal, Equatorial Guinea, Moldova, Botswana, Bulgaria, Bolivia, Bosnia and Herzegovina, Morocco, Montenegro, Kyrgyzstan, Greece, Jamaica, Niger, Libya, Paraguay, Zambia, Argentina, Iran, Serbia. A well-built logistics chains and a partnership network let us to dispatch our units anywhere in the globe promptly without disreputing product quality.
A particular source of dignity for FAMAGA is its team members, each of whom contributes to our work. We request into our team only experts, who already have experience in the range of factory-made equipment.
All items from FAMAGA are verified - we are responsible for the cause of our work. Nowadays, more than 10 million units of products have been supplied, and this bulk is ascending every day. We are pleased that purchasers choose FAMAGA again and again, and we are happy to make more exceptional and technologically modern industrial equipment so as stay in control.
To get some advice or book, contact us or write a message to the online chat on our official website. You can also dispatch a list of the desirable equipment to the email of corporation - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
Model | IV-500C | |
Type | Standard distance | |
Installed distance | 50 to 500 mm | |
View | Installed distance 50 mm: 25 (H) x 18 (V) mm to installed distance 500 mm: 210 (H) x 157 (V) mm | |
Image sensor | Type | 1/3 inch colour CMOS |
Pixel | 752 (H) x 480 (V) | |
Focus adjustment | Manual | |
Exposure time | 1/10 to 1/50,000 | |
Lights | Illumination | White LED |
Lighting method | Pulse lighting/DC lighting is switchable | |
Tools | Type | Shape Detection, Colour Area*1, Area*2, position adjustment |
Number | Detection tools: 16 tools, position adjustment tool: 1 tool*3 | |
Switch settings (programs) | 32 programmes | |
Image history | Numbers | 100 images*4*5 |
Condition | NG only/All is selectable*5 | |
Analysis information | OFF/Statistics/Histograms is switchable Statistics: Processing time (latest value, MAX, MIN, AVE), number of OKs, number of NGs, trigger numbers, trigger errors, judgement results list by tools Histograms: Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs *6 | |
Other functions | HDR, HighGain, Colour filters*1, Digital zoom*2, Brightness correction, Tilt correction, White balance*1, Mask outline, Mask area, Test run, ToolAutoTune, Input monitor, Output test, Security settings, Simulator*7 | |
Indicators | PWR/ERR, OUT, TRIG, STATUS, LINK/ACT | |
Input | Type | Non-voltage input/voltage input is switchable For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V) |
Inputs | 6 inputs (IN1 to IN6) | |
Function | IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions Assignable functions: Program switching, Clear error, External master image registration | |
Output | Type | Open collector output NPN/PNP is switchable, N.O./N.C. is switchable For open collector NPN output: Maximum rating 26.4 V 50 mA, remaining voltage 1.5 V or lower For open collector PNP output: Maximum rating 26.4 V 50 mA, remaining voltage 2 V or lower |
Outputs | 4 outputs (OUT1 to OUT4) | |
Function | Enable by assigning the optional functions Assignable functions: Total judgement result, RUN, BUSY, Error, Position adjustment result, Judgement result of each tool, Result of the logical operation of each tool, Main unit/expansion unit logical output | |
Ethernet | Standard | 100BASE-TX/10BASE-T*8 |
Connector | M12 4pin connector*8 | |
Network function | FTP client, EtherNet/IPTM, PROFINET | |
Rating | Power voltage | 24 VDC ±10 % (including ripple) |
Current consumption | 0.6 A or less | |
Environmental resistance | Enclosure rating | IP67*9 |
Ambient temperature | 0 to +50 °C (No freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions*10 | |
Shock resistance | 500 m/s2, 3 times in each of 6 directions*10 | |
Material | Main unit case: Aluminium die-casting, Packing: NBR, Front cover: Acrylic, Mounting adapter: POM | |
Weight | Approx. 270 g | |
*1 Colour type only *2 Possible with both the colour type and monochrome type *3 Tools can be installed by programmes. *4 When using the FTP client function: 70 pictures *5 Saves to the memory in the sensor. The images saved in the sensor can be backed up to the USB memory installed to the intelligent monitor (IV-M30) or to the PC by the software for IV (IV-H1). *6 This can be displayed on the intelligent monitor (IV-M30) or by software for IV (IV-H1). *7 Simulator can be used with the IV software (IV-H1). *8 This is for connection with the intelligent monitor (IV-M30) or software for IV (IV-H1). *9 Except when polarised filter attachment (OP-87436/OP-87437) is mounted *10 Except when IV-G dome attachment (IV-D10) is mounted |