We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Keyence
Country
Japan
Name
IV-G10
Type
Mounting bracket
Description
For IV-G, evaluation device, main unit
Stock availability:
On request
If you are questing Keyence IV-G10 , communicate with FAMAGA, the world's central company of streamlined equipment. Our company has functioned for more than ten years - these are cycles of experience, which are described in the quality of items and special attention to each client. We cherish everyone, who engaged with us - hence, our regular purchasers bring in the most desirable purchase forms and discounts on the factory-made equipment market. At present, there are more than 4500 such buyers, and we constantly compose new agreements. More than 700 proceedings are resolved per day, because FAMAGA delivers all over the planet Germany, United Kingdom, Gambia, Kiribati, Afghanistan, Jordan, Peru, Guinea, The Gambia, Palestine, Samoa, Eswatini, Egypt, Vietnam, Bulgaria, New Zealand, Ukraine, Liberia, Mauritius, Bosnia and Herzegovina, Uzbekistan, Antigua and Barbuda, Tonga, North Korea, Cyprus, Lithuania, Sudan, Liechtenstein, Ghana, Uganda, Mali, Finland, Kazakhstan, United Arab Emirates, Algeria, Swaziland, Austria, Hungary, Laos, Angola, Argentina, Rwanda, Kyrgyzstan, Iceland, Greece, Senegal, Cape Verde. A well-elaborated logistics system and a partnership network assist us to send our products anywhere in the globe promptly without disreputing product quality.
A particular source of honor for FAMAGA is its employees, each of whom contributes to common cause. We invite into our team only specialists, who already have experience in the range of industrial equipment.
All products from FAMAGA are verified - we are responsible for the result of our work. At this moment, more than 10 million units of products have been provided, and this amount is increasing every day. We are pleased that purchasers choose FAMAGA again and again, and we are happy to make more developed and technologically innovative industrial equipment so as keep on top of it.
To consult or order, get in touch with us or write to the online chat on our official website. You can also dispatch a list of the necessary equipment to the email of firm - we will contact you ourselves with a made commercial proposal from FAMAGA.
Model | IV-G10 | |
Type | Main unit | |
Tools | Type | Shape Detection, Area*1, Colour Area*2, position adjustment |
Number | Detection tools: 16 tools, position adjustment tool: 1 tool*3 | |
Switch settings (programs) | 32 programmes | |
Image history | Numbers | When using a colour type head: 100 images*4, when using a monochrome type head: 300 images*5*6 |
Condition | NG only/All is selectable*6 | |
Analysis information | OFF/Statistics/Histograms is switchable Statistics: Processing time (latest value, MAX, MIN, AVE), number of OKs, number of NGs, trigger numbers, trigger errors, judgement results list by tools Histograms: Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs*7 | |
Other functions | HDR, HighGain, Colour filters*2, Digital zoom (2x, 4x)*8, Brightness correction, Tilt correction, White balance*2, Mask outline, Mask area, Test run, ToolAutoTune, Input monitor, Output test, Security settings, Simulator, Mutual interference prevention, Total judgement result output, Direct connection (2 units or more), Failing sensor list, Failure hold | |
Indicators | PWR/ERR, OUT, TRIG, STATUS, LINK/ACT | |
Input | Type | Non-voltage input/voltage input is switchable For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V) |
Inputs | 6 inputs (IN1 to IN6) | |
Function | IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions Assignable functions: Program switching, Clear error, External master image registration, Main unit/expansion unit simultaneous input | |
Output | Type | Open collector output NPN/PNP is switchable, N.O./N.C. is switchable For open collector NPN output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-G15]), remaining voltage 1.5 V or lower For open collector PNP output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-G15]), remaining voltage 2 V or lower |
Outputs | 8 outputs (OUT1 to OUT8) | |
Function | Enable by assigning the optional functions Assignable functions: Total judgement result, RUN, BUSY, Error, Position adjustment result, Judgement result of each tool, Result of the logical operation of each tool, Main unit/expansion unit logical output | |
Ethernet | Standard | 100BASE-TX/10BASE-T*9 |
Connector | RJ-45 8pin connector*9 | |
Network function | FTP client, EtherNet/IPTM, PROFINET | |
Rating | Power voltage | 24 VDC ±10 % (including ripple) |
Current consumption | 0.8 A or less. 1.5 A or less when also using an expansion unit (IV-G15). (The output load is excluded.) | |
Environmental resistance | Ambient temperature | 0 to +50 °C (No freezing)*10 |
Relative humidity | 35 to 85 % RH (No condensation) | |
Material | Main unit case: Polycarbonate | |
Weight | Approx. 150 g | |
*1 Monochrome type only *2 Colour type only *3 Tools can be installed by programmes. *4 When using the FTP client function: 70 pictures *5 When using the FTP client function: 210 pictures *6 Saves to the sensor amplifier's internal memory. The images saved to the sensor amplifier can be backed up to the USB memory device inserted into the intelligent monitor (IV-M30) or to the PC by the software for the IV/IV-G Series (IV-H1). *7 This can be displayed on the intelligent monitor (IV-M30) or by software for the IV/IV-G Series (IV-H1). *8 Possible with both the colour type and monochrome type *9 This is for connection with the intelligent monitor (IV-M30) or software for the IV/IV-G Series (IV-H1). *10 When attaching the sensor amplifier to a DIN rail, attach the sensor amplifier to a metal plate. |