We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are looking for Keyence FS-N41N , connect FAMAGA, the world's central provider of streamlined equipment. Our company has worked for more than ten years - these are years of experience, which are symbolized in the quality of products and particular attention to each buyer. We understand everyone, who cooperated with us - therefore, our regular consumers get the most favorable purchase terms and discounts on the manufacturing equipment market. Now, there are more than 4000 such purchasers, and we constantly arrange new agreements. More than 650 purchases are terminated per day, because FAMAGA operates all over the earth Germany, United Kingdom, Honduras, Mongolia, Madagascar, Mexico, Norway, France, Haiti, Greece, Nepal, Cyprus, Finland, Jamaica, China, Colombia, Kazakhstan, Eritrea, Turkmenistan, El Salvador, Togo, Nigeria, Cape Verde, Tonga, Mauritius, Estonia, Belarus, Botswana, Guyana, Cameroon, Morocco, Bosnia and Herzegovina, Mauritania, Swaziland, Fiji, Suriname, Samoa, Georgia, Ireland, Serbia, Kyrgyzstan, Luxembourg, Lithuania, Indonesia, Djibouti. A well-elaborated logistics series and a partnership network guide us to dispatch our products anywhere in the world immediately without damaging product quality.
A particular source of dignity for FAMAGA is its personnel, each of whom contributes to common cause. We invite into our team only professionals, who already have experience in the field of machine made streamlined equipment.
All merchandises from FAMAGA are ensured - we are responsible for the aftereffect of our work. At the moment, more than 10 million units of products have been shipped, and this quantity is amounting every day. We are glad that users choose FAMAGA again and again, and we are pleased to make more advanced and technologically advanced industrial equipment so as to stay on the top.
To inquire or make a request, call us by phone or write a message to the online chat on our site. You can also send a list of the needful equipment to the email of firm - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
Model | FS-N41N | |
Type | Cable | |
Output type | NPN | |
Main unit/expansion unit | Main unit | |
Number of control outputs | 1 | |
Number of external inputs | ? | |
Light source LED | Transmitter side: Red, four-element LED (wavelength 660 nm) | |
Response time | 23 µs (S-HSPD*1) / 50 µs (HSPD*2) / 250 µs (FINE) /500 µs (TURBO) / 1 ms (SUPER) / 4 ms (ULTRA) / 16 ms (MEGA) / 64 ms (TERA) | |
Control output | Open-collector, 30 V or less 100 mA or less per output, 100 mA or less total for 2 outputs (when used as a solitary unit) / 20 mA or less (when used as an expansion unit) Residual voltage: 1.4 V or less (output current 10 mA or less) / 2 V or less (output current 10 to 100 mA) | |
External input | Input time 2 ms (ON) / 20 ms (OFF) or longer*3 | |
Unit expansion | Up to 16 units (17 units connected in total including the main unit). However, each dual output type will be treated as two expansion units. | |
Protection circuit | Protection against reverse power connection, output overcurrent, output surge, and reverse output connection | |
Mutual interference prevention | S-HSPD/HSPD 0 units, FINE 4 units, TURBO/SUPER/ULTRA/MEGA/TERA 8 units (The mutual interference prevention values are twice those shown here when Double is set.) | |
Power supply | Power voltage | 10 to 30 VDC (including 10% ripple (P-P) or less) , class 2 or LPS*4 |
Current consumption | During normal operation: 870 mW or less (34 mA or less at 24 V/62 mA or less at 12 V) ECO ON: 800 mW or less (31 mA or less at 24 V/56 mA or less at 12 V) ECO FULL: 710 mW or less (28 mA or less at 24 V/49 mA or less at 12 V)*5 | |
Environmental resistance | Ambient light | Incandescent lamp: 20,000 lux or less, sunlight: 30,000 lux or less |
Operating ambient temperature | -20 °C to +55 °C (no freezing)*6 | |
Vibration resistance | 10 to 55 Hz, double amplitude 1.5 mm, 2 hours each for X, Y, and Z axes | |
Shock resistance | 500 m/s2 , 3 times each for X, Y, and Z axes | |
Case material | Main unit and cover: polycarbonate | |
Weight | Approx. 78 g | |
*1 Restrictions when S-HSPD is selected Area detection, Area % Mode, DATUM, Rising edge, and Falling edge cannot be selected for Detection Mode. Output timer, Limit Detection, and Display Gain cannot be used. FULL cannot be selected for the ECO function. *2 Restrictions when HSPD is selected Display Gain cannot be used. *3 The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected. *4 When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher. *5 The load current is excluded. The power consumption including the load when the maximum number of units are connected is 38 W max. *6 When expanded by 1 to 2 units: -20 °C to +55 °C. When expanded by 3 to 10 units: -20 °C to +50 °C. When expanded by 11 to 16 units: -20 °C to +45 °C. When using 2 outputs, 1 unit is counted as 2 units. The prescribed values for the ambient temperature assume that the sensor amplifier has been mounted on a DIN rail installed on a metal surface. Exercise special care when installing the product in an airtight space. |