Manufacturer
Keyence
Country
Japan
Name
GP-M010
Type
Process Sensor
Description
Druckanzeigender Messumformer Bereich: 0-150 psi Prozessanschluss: BSP
Stock availability:
On request
If you are pursuing Keyence GP-M010 , communicate with FAMAGA, the world's main vendor of manufacturing equipment. Our company has existed for more than ten years - these are ages of experience, which are described in the quality of products and particular attention to each user. We esteem everyone, who joined with us - hence, our regular customers procure the most desirable purchase forms and discounts on the factory-made equipment market. Nowadays, there are more than 4 thousand such purchasers, and we constantly sign new agreements. More than 700 affairs are settled per day, because FAMAGA delivers all over the earth Germany, United Kingdom, Mexico, Iraq, Bahrain, Djibouti, Guinea-Bissau, Switzerland, Lithuania, Lebanon, Turkmenistan, Uganda, Gambia, Burundi, Myanmar, Thailand, Kuwait, Uruguay, Netherlands, Belize, Sierra Leone, Central African Republic, East Timor, Algeria, Costa Rica, New Zealand, South Korea, Kyrgyzstan, Turkey, Israel, Georgia, Montenegro, Nepal, Kiribati, Mongolia, Morocco, Eswatini, Ecuador, Australia, Slovakia, Philippines, Mali, Argentina, North Korea, India, Bangladesh, Dominica, Andorra, Chile. A well-shaped logistics series and a partnership network cheer us to ship our elements anywhere in the globe on-time without undermining product quality.
A particular source of repute for FAMAGA is its team members, each of whom contributes to common cause. We call into our team only professionals, who already have experience in the range of factory-made equipment.
All outputs from FAMAGA are verified - we are responsible for the result of our work. At this moment, more than 10 million units of products have been delivered, and this amount is rising every day. We are pleased that consumers choose FAMAGA again and again, and we are pleased to make more progressive and technologically innovative industrial equipment so as keep on top of it.
To request or order, get in touch with us or write a message to the online chat on our official website. You can also dispatch a list of the needful equipment to the email of firm - we will contact you ourselves with a made commercial proposal from FAMAGA.
Model | GP-M010 | |
Rated pressure | -0.1 to +1 MPa (-1 to +10 bar) | |
Possible display range | -0.210 to +1.110 MPa (-2.10 to +11.10 bar) | |
Zero-cut pressure value | ±0.5% of F.S. | |
Burst pressure | 15 MPa (150 bar) | |
Display resolution | 0.001 MPa (0.01 bar) | |
Fluid type | Gas or liquid that will not corrode the liquid contact part | |
Type of pressure | Gage pressure | |
Precision | ±1.0% of F.S. or less*1 | |
Repeatability | ±0.3% of F.S. or less*2 | |
Temperature characteristics | ±0.6% of F.S./10°C | |
Connection diameter | G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.) | |
Box rotation angle | Maximum 330° | |
Medium temperature | -20 to +100°C (no freezing/condensation)*3 | |
Power supply voltage | 10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS | |
Current consumption | 50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4 | |
Display method | 4 column, digital LED, red/Vertical inversion display possible | |
Operation display light | Operation indicator (output 1) (orange), Operation indicator (output 2) (orange) | |
Hysteresis | During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis) During window mode: fixed (0.5% of F.S.) | |
Response | Control output | Selectable from 3 to 5000 ms |
Analogue output | As above + 2 ms (90% response) | |
Output | Output 1 control output | NPN/PNP open collector (Selectable), Max. 250 mA (30 V max) Main unit residual voltage 1 V max, N.O./N.C. selectable |
Output 2 replacement type | Control output | |
Analogue output | 4-20 mA, maximum load resistance 500 ? (When the electric voltage is more than 20 V)*5 | |
Environmental resistance | Enclosure rating | IP67 |
Pressure resistance | 4 MPa (40 bar) | |
Ambient temperature | -20 to +80 °C (No freezing and no condensation) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axes) | |
Shock resistance | IEC60068-2-27 50G (11 ms, 3 times for each of X, Y and Z direction) | |
Material properties | Port/diaphragm | Pressure port: SUSXM7, Diaphragm pressure port: Al2O3 (Alumina), O ring: FKM |
Other parts | Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU, Air hole: PTFE, nickel-plated brass. | |
Applicable cable | M12 connector 4 pin | |
Weight | Approx. 150 g | |
*1 This is the value when considering linearity + hysterisis + repeatability in a stable environment of 23°C. *2 The repeatability, based on consistent conditions, is the difference in the detection points at the time of fluctuations in the repetition. *3 When the temperature of the piping exceeds 80°C, do not connect the cable. *4 Consumption current including output is 0.6 A and under. *5 The maximum load resistance R will be the values below in response to the electric voltage E. When 10-23V: R = {38 x (E-10) + 128} ? When 23-30V: R = 622 ? |