We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are questing Keyence VK-X110 , connect FAMAGA, the world's key producer of factory-made equipment. Our company has lasted for more than ten years - these are cycles of experience, which are depicted in the quality of merchandises and individual attention to each consumer. We understand everyone, who worked with us - therefore, our regular clients obtain the most convenient purchase forms and discounts on the industrial equipment market. At this time, there are more than 4000 such clients, and we constantly compose new agreements. More than 650 proceedings are resolved per day, because FAMAGA operates all over the world Germany, United Kingdom, Dominican Republic, Tanzania, Ireland, Guinea, Belgium, Guyana, Samoa, Uruguay, Mauritania, Estonia, Nigeria, Swaziland, Albania, Guatemala, Finland, Mali, United States, Argentina, Peru, North Korea, Morocco, Qatar, Cape Verde, Croatia, Latvia, Togo, Iceland, Syria, Haiti, Mongolia, Fiji, Senegal, Belarus, Serbia, Georgia, Zimbabwe, Bosnia and Herzegovina, Iran, Pakistan, Lithuania, Seychelles, Jamaica. A advanced logistics bond and a partnership network let us to conduct our units anywhere in the world promptly without undermining product quality.
A particular source of good name for FAMAGA is its workers, each of whom contributes to our work. We propose into our team only experts, who already have experience in the field of industrial equipment.
All goods from FAMAGA are ensured - we are responsible for the outcome of our work. At the moment, more than 10 million units of products have been shipped, and this number is increasing every day. We are proud that purchasers choose FAMAGA again and again, and we are pleased to make more advanced and technologically developed industrial equipment so as not to lower the bar.
To inquire or place an order, call us by phone or write a message to the online chat on our official website. You can also send a list of the required equipment to the email of our company - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
Model | VK-X110 | ||
Type | Measurement unit | ||
Objective lens magnification | Magnification on a 15” monitor 200x | 10? | |
Magnification on a 15” monitor 400x | 20? | ||
Magnification on a 15” monitor 1000x | 50? | ||
Magnification on a 15” monitor 2000x | 100? | ||
Observation/ measuring range | Horizontal (H): ?m | Magnification on a 15” monitor 200x | 1350 |
Magnification on a 15” monitor 400x | 675 | ||
Magnification on a 15” monitor 1000x | 270 | ||
Magnification on a 15” monitor 2000x | 135 | ||
Vertical (V): ?m | Magnification on a 15” monitor 200x | 1012 | |
Magnification on a 15” monitor 400x | 506 | ||
Magnification on a 15” monitor 1000x | 202 | ||
Magnification on a 15” monitor 2000x | 101 | ||
Working distance: mm | Magnification on a 15” monitor 200x | 16.5 | |
Magnification on a 15” monitor 400x | 3.1 | ||
Magnification on a 15” monitor 1000x | 0.54 | ||
Magnification on a 15” monitor 2000x | 0.3 | ||
Numerical Aperture (N.A.) | Magnification on a 15” monitor 200x | ||
Magnification on a 15” monitor 400x | 0.46 | ||
Magnification on a 15” monitor 1000x | 0.8 | ||
Magnification on a 15” monitor 2000x | 0.95 | ||
Optical zoom | 1x to 8x | ||
Total magnification | 200x to 16000x | ||
Optical system for observation/measurement | Pinhole confocal optical system | ||
Height measurement | Measuring range | 7 mm | |
Z-resolution | 0.005 µm | ||
Repeatability ? | 0.02 µm*1 | ||
Width measurement | Display resolution | 0.01 µm | |
Repeatability 3? | 0.03 µm*2 | ||
Frame memory | Pixel count | 2048 x 1536, 1024 x 768, 1024 x 64 | |
For monochrome image | 16 bit | ||
For colour image | 8-bit for RGB each | ||
For height measurement | 21-bit | ||
Frame rate | Surface scan | 4 Hz to 120 Hz | |
Line scan | 7900 Hz | ||
Auto function | AAG (Auto gain), Auto focus, Auto upper/lower limit setting, Double Scan brightness settings | ||
Measurement laser light source for measurements | Wavelength | Red semiconductor laser, 658 nm | |
Maximum output power | 0.95 mW | ||
Laser Class | Class 2 Laser Product (IEC 60825-1, FDA (CDRH) Part1040.10 *3) | ||
Laser light-receiving element | PMT (Photoelectron Multiplier Tube) | ||
Light source for optical observation | Lamp | 100 W halogen lamp | |
Colour camera for optical observation | Imaging element | 1/3' Colour CCD image sensor | |
Recording resolution | Super high resolution (3072?2304) | ||
Auto adjustment | Gain, Shutter speed | ||
Data processing unit | Dedicated PC, supplied by KEYENCE with the VK-X (OS: Windows 7 Professional Edition) *4 | ||
Software | Auto-focus software | This is software that automatically focuses the image during observation. | |
Pixel shift software | This is software that increases the number of pixels recorded by shifting pixels during image recording. | ||
HDR function software | This is software that obtains 16-bit data to optimize the image appearance. | ||
RPD function software | This is an algorithm that detects the measurement result quickly and accurately. | ||
AAG function software | This is software that automatically adjusts the laser light-receiving sensitivity within the setting range. | ||
Auto upper/lower limit setting software | This is software that automatically recognizes the upper and lower limits of the target and sets the measurement range. | ||
Beginner mode function software | This is software that can be used to easily perform measurements as flow charts. | ||
Comment function software | This is software that displays comments on the observation screen. | ||
Measurement and scale display software | This is software that displays a scale on the dimension measurement and observation screen. | ||
Rating | Power voltage | 100 to 240 VAC ±10 %, 50/60 Hz | |
Power consumption | 450 VA max. | ||
Weight | Approx. 25 kg (Measuring head detached: approx. 8.5 kg) | ||
*1 When a standard height difference of 2 µm is measured with the 50x objective lens. *2 When the KEYENCE reference chart line width of 1 µm is measured with the 100 x objective lens in line peak mode (image averaging: 8 times). *3 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *4 Windows 7 is a registered trademark of Microsoft, U.S.A. |