We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are looking for Keyence IM-6145 , make contact with FAMAGA, the world's influential vendor of machine made equipment. Our company has functioned for more than ten years - these are years of experience, which are described in the quality of goods and personalseparate attention to each purchaser. We praise everyone, who joined with us - thus, our regular customers procure the most desirable purchase conditions and discounts on the machine made streamlined equipment market. At this moment, there are more than 3500 such customers, and we constantly form new agreements. More than 700 transactions are made per day, because FAMAGA delivers all over the globe Germany, United Kingdom, Honduras, Tunisia, Kazakhstan, Lesotho, Ecuador, Pakistan, North Korea, Liberia, Monaco, Mongolia, Liechtenstein, Uzbekistan, Turkey, Cameroon, South Sudan, Azerbaijan, El Salvador, Antigua and Barbuda, The Gambia, Turkmenistan, Uruguay, Lithuania, Sweden, Chad, Nepal, Kiribati, Equatorial Guinea, The Bahamas, Argentina, Slovakia, Bosnia and Herzegovina, Rwanda, Luxembourg, Tonga, Haiti, Paraguay, Chile, Burkina Faso, Albania, Sierra Leone, Algeria, Norway, Poland. A well-developed logistics connection and a partnership network allow us to deliver our goods anywhere in the globe as soon as possible without compromising product quality.
A special source of pride for FAMAGA is its employees, each of whom contributes to our work. We accept into our team only professionals, who already have experience in the range of factory-made equipment.
All spare parts from FAMAGA are guaranteed - we are responsible for the cause of our work. Nowadays, more than 10 million units of products have been supplied, and this bulk is growing every day. We are pleased that customers choose FAMAGA again and again, and we strive to make more exceptional and technologically modern industrial equipment so as stay in control.
To consult or book, contact us or write to the online chat on our official website. You can also dispatch a list of the desirable equipment to the email of corporation - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
Model | IM-6145 | |
Type | Measurement head | |
Image sensor | 1' 6.6 mega pixel CMOS | |
Display | 10.4' LCD monitor (XGA: 1024 ? 768) External monitor connectable (clone output) | |
Receiver lens | Double telecentric lens | |
Image measurement | Field of view | Wide-field measurement mode: o25 mm High-precision measurement mode: o6 mm |
Minimum display unit | 0.1 µm | |
Repetition accuracy | Wide-field measurement mode: ±0.5 µm High-precision measurement mode: ±0.1 µm | |
Measurement accuracy (±2?) | Wide-field measurement mode: ±2 µm*1 High-precision measurement mode: ±0.7 µm*2 | |
External remote input | No-voltage input (with contacts, without contacts) | |
External output | OK/NG/FAIL/MEAS. | Relay outputRated load 24 VDC 0.5AON resistance 50 m? or less |
Interface | LAN | RJ-45 (10BASE-T / 100BASE-TX / 1000BASE-T) |
USB 2.0 series A | 6 ports (front: 2, rear: 4) | |
Record | Hard disk drive | 250 GB |
Illumination system | Transparent | Telecentric transparent illumination (Green LED) |
Ring | Four division ring illumination (White LED) | |
Coaxial epi-illumination (white LED) | ||
External | Externally connected illumination | |
X stage | Moving range | Within o25 mm field |
Z stage | 20 mm | |
Withstand load | 1 kg | |
Y stage | Moving range | Within o25 mm field |
Power supply | Power voltage | 100 to 240 VAC 50 / 60 Hz |
Power consumption | 310 mA or less | |
Environmental resistance | Ambient temperature | +10 to +35 °C |
Relative humidity | 20 to 80 % RH (No condensation) | |
Weight | Approx 25 kg | |
*1 In the range of o20 mm from the centre of the stage at the operating temperature range of +23 ±1°C at the focused focal point position *2 In the range of o5 mm from the centre of the stage at the operating temperature range of +23 ±1°C at the focused focal point position |