Measurement Systems IM-7030 Keyence
Measurement Systems IM-7030 Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

IM-7030 Keyence Measurement Systems

Manufacturer

Keyence

Country

Japan

Name

IM-7030

Type

Measurement Systems

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications IM-7030

If you are inspecting Keyence IM-7030 , contact FAMAGA, the world's prime distributor of streamlined equipment. Our company has progressed for more than ten years - these are ages of experience, which are expressed in the quality of products and particular attention to each user. We appreciate everyone, who conspired with us - therefore, our regular purchasers accept the most favorable purchase terms and discounts on the industrial equipment market. Today, there are more than 4000 such purchasers, and we constantly arrange new agreements. More than 650 affairs are settled per day, because FAMAGA operates all over the world . A well-shaped logistics series and a partnership network guide us to ship our items anywhere in the world on-time without damaging product quality.

A specific source of repute for FAMAGA is its personnel, each of whom contributes to our work. We call into our team only specialists, who already have experience in the field of industrial equipment.

All outputs from FAMAGA are affirmed - we are responsible for the outcome of our work. At the moment, more than 10 million units of products have been shipped, and this number is amounting every day. We are proud that consumers choose FAMAGA again and again, and we are glad to make more advanced and technologically developed industrial equipment so as not to lower the bar.

To request or place an order, call us by phone or send a message to the online chat on our official website. You can also send a list of the required equipment to the email of our company - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.

Features IM-7030

Measurement Head
Model IM-7030
Type Head Wide stage model incorporating programmable ring-illumination/light probe unit
Image sensor 1” 6.6 mega pixel monochrome CMOS
Display 10. 4” LCD monitor (XGA: 1024 ? 768)
Receiver lens Double telecentric lens
Image measurement Field of view Wide-field measurement mode: 300 mm ? 200 mm (4? R50) High-precision measurement mode: 225 ? 125 mm
Minimum display unit 0.1 µm
Repeatability W/o stage movement Wide-field measurement mode: ±1 µm High-precision measurement mode: ±0.5 µm
With stage movement Wide-field measurement mode: ±2 µm High-precision measurement mode: ±1.5 µm
Measurement accuracy (±2?) W/o binding Wide-field measurement mode: ±5 µm*1 High-precision measurement mode: ±2 µm*2
With binding Wide-field measurement mode: ±(7 + 0.02 L) µm*3 High-precision measurement mode: ± (4 + 0.02 L) µm*4
Light probe Measurement Measurable area (XY) 190 ? 90 mm
Maximum measurement depth 30 mm
Light probe diameter o3 mm
Measuring force 0.015 N
Repeatability ±2 µm*5
Measurement accuracy ±(8 + 0.02 L) µm*6
External remote input Non-voltage input (with and without contact)
External output OK/NG/FAIL/MEAS. PhotoMos output Rated load 24 VDC 0.5 A ON resistance 50 m? or lower
Interface LAN RJ-45 (10BASE-T/100BASE-TX/1000BASE-T)
USB 2.0 series A 6 ports (front: 2, rear: 4)
Record Hard disk drive 500 GB
Illumination system Transparent Telecentric transparent illumination
Ring Four division, multi-angle illumination (electric) Slit ring (directivity) illumination (electric)
XY stage Moving range 200 ? 100 mm (electric)
Withstand load 7.5 kg
Z stage Moving range 75 mm (electric)
Power supply Power voltage 100–240 VAC, 50/60 Hz
Current consumption 430 VA or lower
Environmental resistance Operating ambient temperature +10°C to 35°C
Operating ambient humidity 20% RH to 80% RH (no condensation)
Weight Approx. 33 kg
*1 In the range of o80 mm, within the operating ambient temperature range of +23°C ±1°C at the focused focal point position *2 In the range of o20 mm within the operating ambient temperature range of +23°C ±1°C at the focused focal point position *3 In the range of 280 ? 180 mm (4? R40), within the operating ambient temperature range of +23°C ±1°C at the focused focal point position, and with a load weighing 3 kg or less on the stage (L = amount of stage movement in mm units) *4 In the range of 220 ? 120 mm, within the operating ambient temperature range of +23°C ±1°C at the focused focal point position, and with a load weighing 3 kg or less on the stage (L = amount of stage movement in mm units) *5 When the detection system is standard. If the detection system is at a deep position, then ±3 µm *6 When the detection system is standard, and the ambient temperature is +23°C ±1°C, with a stage load weighing 3 kg or less. If the detection system is at a deep position,then ±(10 + 0.02 L) µm with L as the measurement length in mm.