'

We are not the manufacturer, authorised distributor or authorised representative of the Honeywell brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

Honeywell – page 15

Selling any product from the catalog Honeywell at good prices

Vendor code
Description
Price
On request
Get a price
BCU460W3P2C0D0000K1E0-/LM400WF0O0E1- Burner control unit BCU 4 On-site housing, for controlling, igniting and and monitoring of pulse-controlled/step-controlled or modulating controlled gas burners. For continuous or intermittent operation with ionization or UV monitoring. Display of the program status, the unit parameters and the flame signal. Manual operation mode. Diagnosis and setting of the unit parameters via optical interface and PC software BCSoft. Optional fieldbus connection to PROFIBUS, Ethernet/IP, PROFINET, incl. SafetyLink between the BCU 4 and the FCU. Furthermore interfaces for air valve or actuator IC, valve monitoring system (VPS), leakage control TC or POC as well as functionalities for high temperature applications and low-NOx operation (menox®). EC type tested and certified, FM approved, certified for systems up to SIL3. Device type Part1 BCU Device type part2 460 Mains voltage 230VAC 50/60Hz Ignition transformer 8kV100ED Flange plate M32 Connection plug Screw terminals Power supply Power supplySK Device type part1 LM Device type part2 400 O1_Mains voltage 230VAC 50/60Hz O2_air actuator Without O3_Optional output Without ID Output module Version Power supplyL1 F001 Valve monitoring system Without F002 High temperature operation Without F004 Start conditions LDS Off F005 Additional gas function (V4) Off F003 Sensor functions None I004 Flame monitoring Ionization I020 Air actuator Off I040 Function terminal 64 Off I050 Function contact 80,81/82 Fault message I051 Function contact 90,91/92 Off I052 Function contact 95/96 Operating message Burner 1 I053 Function contact 95/97 Operating message Burner 1 I054 Function contact 85/86,87 Off I061 Function terminal 1 Start 1 I062 Function terminal 2 Reset I063 Function terminal 3 Off I064 Function terminal 4 Off I065 Function terminal 5 Off I066 Function terminal 6 Off I067 Function terminal 7 Off I068 Function terminal 35 SK I069 Function terminal 36 Off I070 Function terminal 37 Off I071 Function terminal 38 Off I072 Function terminal 39 Off I073 Function terminal 40 Off I074 Function terminal 41 Off I095 Password LVL5 1234 A001 Switch-off threshold 1 2μA A002 Switch-off threshold 2 5μA A003 External light check in standby A007 Start-up tests burner 1 1 Start-up attempt A093 Pre-ignition time 0 s A094 Safety time 1 5 s A095 Flame rod time 1 0 s A078 Burner application two-stage burner 1 A009 Restart Off A074 Combustion mode Flame mode A043 Overrun Off A039 Overrun time 0 s A019 Safety time operation 1 s A061 Min. operating time 0 s A062 Min. pause 30 s A067 Operating time manual mode 5 min. A080 Fieldbus communication Off A081 "K" Safety Link Off
On request
Get a price
STG74L-E1H000-1-C-CHC-13C-B-21A6-TP,FX,FG,FE,F1-0 STG74L - STG74L Process Head and Diaphragm Mat: Head Mat 316SS/Diaph 316LSS - E Fill Fluid: Silicone Oil 200 - 1 Process Connection: 1/2 inch NPT; male - H Bolt/Nuts Materials: None - 0 Vent Drain Type; Location: None - 0 Gasket Materials: None - 0 Head; Connect Orientation: Standard; High Side Left - 1 Approvals: ATEX Exproof/IS/NI - C Elec Housing Mat Conn Type: Alum; 1/2 NPT; LP Yes - C Output Protocol: Output 4-20mAdc with HART - H Customer Interface Selections: Basic Ind; Buttons; English - C Configuration Selection App SW: Standard Diagnostics - 1 O/P LMT Fail and Protect Sett: WP: Enabled; Fail: High - 3 General Configuration: Cust Config Unit Data Required - C Accuracy and Calibration: Std Acc; Cust; Sigl Calib - B Accessory sel Mounting Bracket: Bkt Type;Angle Bkt;Mat; 304 SS - 2 Customer Tag Type: One Wired Stainless Steel Tag - 1 Unassembled Conduit Adapter: 1/2 NPT 316 SS Cert Conduit - A6 Certifications and Warranty: NACE Process wetted parts only, EN10204 Type 3.1 Mat Trace, Cal Tst Rep & Ct of Conf-F3399, FMEDA SIL 2/3 Cert; FC33337, Over-Pressure Leak Test Cert - FG ,FX ,F1 ,FE ,TP Manufacturing Specials: Factory Identification - 0000 Std/non-Std Leadtime: HigherLeadtime Option Selected - Y Conformity: Linear - L Damping Time for PV: 0.50 - 0.5 Message for Damping entered: Damping entered is correct - Y Polling Address: 0 - 0.0 Loop Current mode: Enable - 1 NAMUR: Disable ; 3.8-20.8 mA - 2 SV Unit: Degrees C - 19 Cut off Method: Single Breakpoint - 1 User breakpoint: 7.07 - 7.07 Write Protection: Disable - 2 Basic Display - PV Display: Pressure PV - 1 Basic Display - Units: PSI - 06 Basic Display - Decimals: 1 - 1 Special Options?: No - N
On request
Get a price
On request
Get a price

The site contains only a small part of the catalog items Honeywell.

If you have not found the article you need, send a request to the mail [email protected] and we will definitely send you a commercial proposal.

You can buy products of other brands